To reset the total counter value, you can send the following SMS message to the unit.
Text Command:
*CLA[N]#
N stands for Input number 58
Example:
When *CLA5# is applied, means the total increment counter value will be reset for
input 5
It is possible to sound the alarm manually by sending the following SMS command to the
unit, which remain active for the period of time set.
Text Command:
*ALNF#X
X stands for ON (1) or OFF (0) value
When *ALNF#1 is applied, means audible alarm will sound.
When *ALNF#0 (Default) is applied, means audible alarm will turn off.
To check siren status, you can send *ALNF?#
To check the signal strength (0-31), you would send the following SMS command to the
unit.
Text Command:
*CSQ?#
It is possible to check the system is operating correctly by sending the following SMS
command to the unit.
5.7.7 Reset the Total Increment Counter Value
5.7.9 Checking Signal Strength
5.7.10 Checking the System is Operating Correctly
5.7.8 Sound the Audible Alarm Manually