13
b) Opto-isolated Input.
The use of opto-isolated input is a switch operated. Operate to enable
TLP 181, the input must be between the range of 3V to 30V (Screw terminal
blocks M2, M3). If put in the opto-isolated voltage does not meet the prescribed
range, the TLP181 is not to operate. These applications can be seen more clearly
by further explanation. As an input to the Opto-Isolated reaches 3V TLP 181 will
operate and cause the transistor to send data to the microcontroller. Enter the
micro controller will receive a logic 1 (ON) if TLP181 operate and will receive a
logic 0 (OFF) if the input opto-Isolated input is less than 3V or greater than 30V
[3].
Figure 2.8 Schematic Diagram Opto-Isolated Inputs
c) MOSFET Outputs
MOSFETs are used both as discrete devices and as active elements in
digital and analog monolithic integrated circuits. in this circuit, MOSFETs
output should be connected to screw terminal blocks M6 and M7. MOSFET can
Vedere la pagina 28